Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Arq. bras. oftalmol ; 84(6): 554-560, Nov.-Dec. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1350068

ABSTRACT

ABSTRACT Purpose: This study aimed to identify patient's reason for no-show at a university eye clinic after ophthalmic examination via a mobile ophthalmic unit, which provides comprehensive ophthalmic care to underserved communities in a region of Brazil. Methods: In 2017/2018, this prospective observational study searched for no-shows at referrals to a university eye clinic after an outreach program screening via a mobile ophthalmic unit in 10 municipalities in the central-western region of São Paulo, Brazil. A total of 1,928 patients underwent a comprehensive eye examination at no cost, and 37.1% of them needed referral to a university eye clinic for specialized examinations or surgeries. We used the following two main tools: (1) comparative analysis between patients who attended the referral and those who did not; (2) active search using a questionnaire to assess reasons for no-show. Results: Attendance to referrals was not influenced by age, gender, distance from the university hospital, number of ophthalmologists in the municipality, average family income, and visual acuity. The main cause for referrals was cataract (350 cases). No-show was most common among glaucoma/suspected glaucoma (54.1%) cases, followed by strabismus (45%) and anterior segment disease (33.6%) cases. Many patients who did not attend the referral sought another service. Conclusion: Patient's issues and lack of knowledge regarding their ophthalmic condition are the main reasons for no-show at referrals for free ophthalmic care. Thus, educational campaigns are needed to achieve consistently high attendance to prevent avoidable blindness.


RESUMO Objetivo: Avaliar as razões para não comparecimento à clínica oftalmológica da universidade após triagem oftalmológica realizada usando uma unidade móvel oftalmológica que fornece exame oftalmológico para comunidades não assistidas em uma região do Brasil. Métodos: Foi realizado um estudo observacional prospectivo no ano de 2017/2018 para avaliar as razões que fizeram com que os indivíduos triados usando uma unidade móvel oftalmológica e referenciados para a clínica oftalmológica da universidade não comparecessem à consulta agendada. A triagem foi feita em 10 municípios da região centro-oeste do estado de São Paulo, Brasil. Todos os 1.928 participantes fizeram o exame oftalmológico sem custo e 37,1% deles necessitaram de encaminhamento para a clínica oftalmológica da universidade para exames especializados ou cirurgias. O estudo usou duas ferramentas: (1) análise comparativa entre os dados dos indivíduos encaminhados que compareceram ao agendamento com os que não compareceram; (2) busca ativa dos indivíduos que não compareceram à consulta agendada, aplicando-se um questionário para avaliar os motivos para o não comparecimento. Resultados: Fatores como idade, sexo, distância entre a cidade de origem e o hospital universitário, número de oftalmologistas na cidade de procedência, renda familiar média e acuidade visual não influenciaram no comparecimento ao encaminhamento. Catarata foi a maior causa para o encaminhamento (350 casos). O não comparecimento foi maior nos portadores de glaucoma/glaucoma suspeitos (54,1%), estrabismo (45%) e afecções do segmento anterior (33,6%). Muitos indivíduos que não compareceram ao serviço de referência procuraram por outro local para o atendimento oftalmológico. Conclusão: O não comparecimento para tratamento oftalmológico sem custo depende de fatores relacionados ao paciente ou à falta de conhecimento das próprias condições oftalmológicas. Campanhas educativas nas comunidades assistidas devem ser feitas para alcançar maior comparecimento às consultas e melhor prevenir a cegueira evitável.

2.
Rev. bras. oftalmol ; 75(3): 209-213, tab
Article in Portuguese | LILACS | ID: lil-787693

ABSTRACT

RESUMO Objetivo: Avaliar a utilidade do tonômetro de ar (TA) em estudos populacionais em indivíduos suspeitos de hipertensão ocular, comparando os valores com os fornecidos pelo tonômetro de aplanação de Goldmann (TG). Métodos: Estudo transversal, de amostra probabilística, composta por 11.452 indivíduos e"20 anos, compondo-se uma subamostra dos que apresentaram valores de pressão intraocular (PIO) obtidos com o TA e"20mmHg, nos quais a PIO foi repetida com o TG. Os resultados dos dois tonmetros foram comparados considerando sexo, cor da pele referida, lateralidade, relação escavação/disco (Â0,6; entre e"0,6 e <0,8; e"0,8) e diagnóstico. Foram consideradas três situações: não-portadores de glaucoma (NG), suspeitos (SG) e portadores de glaucoma (CG). Para comparação entre as medidas foi utilizado o teste t de Student para amostras pareadas e o teste de correlação de Pearson para avaliar a associação entre PIO, idade e tonometria. Resultados: Foram detectados 198 indivíduos (339 olhos) com PIOe"20mmHg com o TA, que tiveram a medida repetida com o TG. Foram considerados 233 olhos como NG, 47 olhos como SG e 19 olhos como CG. Em olhos com escavação e"0,8, a medida com TA e TG foram semelhantes. Nos NG e SG, o TA superestimou os valores. Houve associação entre aumento da PIO e aumento da idade com os dois tonmetros. Conclusão: Valores de PIO são superiores com TA comparados ao TG, principalmente quando a PIO é normal. Há concordância entre os métodos quando a PIO é alta e a escavação do nervo óptico é aumentada, o que valida a aplicação do TA em campanhas populacionais.


ABSTRACT Purpose: to evaluate the use of air tonometer (TA) in population studies in individuals suspected of ocular hypertension, comparing values with those provided by the Goldmann Tonometer (GT). Methods: a cross-sectional study was done using a probabilistic sample consisting of 11,452 individuals e"20 years old.A subsample composed by the individuals with IOP values obtained with TA e"20 mmHg was selected, in which IOP was repeated with the GT. The results of both tonometers were compared considering gender, referred color of skin, laterality, cup-to-disc ratio (Â0.6; e"0.6 and <0.8; e"0.8) and diagnosis, considering three situations: without glaucoma (NG), suspected glaucoma (SG) and patients with glaucoma (CG). The Student t test was used for paired samples and the Pearson correlation test to evaluate the association between IOP, age and tonometry. Results: we identified 198 individuals (339 eyes) with IOP e"20mmHg with the TA, who had the measures repeated with the GT. Two hundred and thirty-three eyes were considered as NG, 47 eyes as SG and 19 eyes as CG. In eyes with cup-to-disc ratio e"0.8, the TA and GT measurements were similar. In NG and SG, the TA overestimated values. There was an association between increased IOP and increasing age with both tonometers. Conclusion: IOP values are higher with TA compared to GT, especially when IOP is normal.There is agreement between the methods when IOP is high and the optic nerve excavation is increased, which validates the application of TA in population campaigns.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Tonometry, Ocular/statistics & numerical data , Comparative Study , Glaucoma/diagnosis , Glaucoma/epidemiology , Ocular Hypertension/diagnosis , Ocular Hypertension/epidemiology , Cross-Sectional Studies , Probability , Cornea/physiology , Observational Study , Intraocular Pressure/physiology
3.
Acta cir. bras ; 28(9): 632-640, Sept. 2013. ilus, tab
Article in English | LILACS | ID: lil-684436

ABSTRACT

PURPOSE: To investigate and compare the biocompatibility of two types of Ferrara intracorneal ring segment: with and without chondroitin sulfate coating by clinical and histopathological evaluation. METHODS: A randomized experimental study was carried out on thirty right-eye corneas from 30 Norfolk albino rabbits allocated into two experimental groups: Group G1 - implanted with Ferrara intracorneal ring segment without coating (FICRS) and Group G2 - implanted with Ferrara intracorneal ring segment with chondroitin sulfate coating (FICRS-CS). Left eyes formed the control group. Clinical parameters analyzed were: presence of edema, vascularization, infection and ring extrusion one, 30, and 60 days after surgery. Histopathological parameters analyzed were: number of corneal epithelial layers over and adjacent to the ring, presence of spongiosis, hydropic degeneration, basement membrane thinning, inflammatory cells, neovascularization and pseudocapsule formation. RESULTS: At clinical examination 60 days after implant, edema, vascularization and extrusion were observed respectively in 20%, 26.7%, 6.7% of FICRS corneas and in 6.7%, 6.7%, and 0% of FICRS-CS corneas. Histopathological evaluation showed epithelial-layer reduction from 5 (5;6) to 3 (3;3) with FICRS and from 5 (5;5) to 4 (3;5) with FICRS-CS in the region over the ring. Epithelial spongiosis, hydropic degeneration, and basement membrane thinning were present in 69.2%, 53.8%, and 69.2% of FICRS and in 73.3%, 73.3%, and 46.7% with FICRS-CS, respectively. Vascularization was present in 38.5% of FICRS and 13.3% with FICRS-CS, inflammatory cells in 75% of FICRS and 33.3% with FICRS-CS, and pseudocapsule in 66.7% of FICRS and 93.3% with FICRS-CS. Giant cells occurred only in the FICRS-CS group (20%). CONCLUSION: Ferrara intracorneal rings coated with chondroitin sulfate (FICRS-CS) caused lower frequency of clinical and histopathological alterations than Ferrara intracorneal rings without the coating (FICRS), demonstrating higher biocompatibility of the FICRS-CS.


Subject(s)
Animals , Female , Rabbits , Biocompatible Materials/therapeutic use , Chondroitin Sulfates/therapeutic use , Corneal Stroma/surgery , Prostheses and Implants , Prosthesis Implantation/methods , Corneal Diseases/surgery , Corneal Stroma/anatomy & histology , Materials Testing , Prosthesis Fitting , Random Allocation , Reference Values , Reproducibility of Results , Time Factors , Treatment Outcome
4.
Arq. bras. oftalmol ; 65(2): 229-233, mar.-abr. 2002. tab, graf
Article in Portuguese | LILACS | ID: lil-308660

ABSTRACT

Objetivo: Estudar os efeitos de duas drogas utilizadas no tratamento de hipertensäo arterial sistêmica (captopril e propranolol) sobre a pressäo intra-ocular (PIO) e pressäo de perfusäo (PP) em cäes anestesiados. Métodos: Foram estudados 24 cäes, divididos em 3 grupos de 8. No primeiro grupo (GI), foi administrado captopril (um inibidor da enzima conversora de angiotensina) na dose de 1,5 mg/kg por via endovenosa. No segundo grupo (GII), foi administrado propranolol (um beta-bloqueador) na dose de 1,5 mg/kg por via endovenosa. O terceiro grupo (GIII) foi o grupo controle. A PIO e a pressäo arterial média (PAm) foram medidas por manometria. A pressäo de perfusäo (PP) foi calculada pela diferença entre a PAm e a PIO. A freqüência cardíaca (FC) foi monitorada com oxímetro de pulso. Os parâmetros foram estudados em 6 momentos (0,10, 30, 60,90 e 120 minutos). Resultados: Houve reduçäo estatisticamente significativa da PIO(p<0,05) nos grupos em que foram administrados captopril e propranolol, sem diferença entre as drogas. Com captopril, houve reduçäo da PAm e da PP aos 10 e 30 minutos. Com propranolol, näo houve reduçäo da PAm ou da PP. Conclusäo: Houve reduçäo da PIO com uso do captopril e também do propranolol. Entretanto, a reduçäo acentuada da PAm e da PP causadas pelo captopril, podem ser indesejáveis para a irrigaçäo do nervo óptico.


Subject(s)
Animals , Dogs , Angiotensin-Converting Enzyme Inhibitors , Adrenergic beta-Antagonists/therapeutic use , Captopril , Hypertension/drug therapy , Intraocular Pressure , Propranolol , Manometry
5.
Radiol. bras ; 28(5): 253-257, set.-out. 1995. graf
Article in Portuguese | LILACS | ID: lil-423001

ABSTRACT

Estudo de 146 olhos com catarata examinados com ultr-som, para medida do comprimento axial (IL) e cálculo de lente intra-ocular (LIO). Encontramos 17,8 por cento de olhos "curtos" (L menor que 22 mm), 58,2 por cento de olhos "médios" (L maior ou igual a 22 mm e menor que 24,5 mm) e 24,00 por cento de olhos "longos" (L maior ou igual a 24,5 mm). As LIOs mais frequentes se situaram na faixa de +19,50D a +23,50D. A diferença média entre as medidas dos dois olhos foi de 0,60 mm. O erro de predição da LIO foi menor que +-1,00D em 60 por cento e menor que +-2,00D em 80 por cento de 15 olhos operados. Comentamos o uso do ultra-som para cálculo da LIO e sua importância na cirurgia de extração de catarata, enfatizando sua necessidade, especialmente em pacientes míopes ou com olhos longos e curtos. O implante da LIO na dioptria indicada está relacionado com o maior conforto visual do paciente no pós-operatório.


Subject(s)
Child , Adolescent , Adult , Middle Aged , Male , Female , Humans , Cataract Extraction , Cataract , Lens Implantation, Intraocular
6.
Rev. bras. oftalmol ; 56(6): 73-8, dez. 1994. ilus, tab
Article in Portuguese | LILACS | ID: lil-148538

ABSTRACT

Os autores analisaram 81 casos de cavidade anoftálmica atendidos no Ambulatório de Cirurgia Plástica Ocular, do Serviço de Oftalmologia da Faculdade de Medicina de Botucatu - UNESP, no período de janeiro de 1986 a dezembro de 1992. Sessenta e nove porcento dos pacientes eram do sexo masculino. A causa mais frequente da perda do globo foi a endoftalmite (24,7 por cento), seguida pelos traumas, Phthisis bulbi e outras. Em 61,7 por cento dos pacientes foi realizada a evisceraçäo e em 38,3 por cento, a enucleaçäo. O implante de cavidade mais utilizado foi a esfera de Mulles de 18 mm. As complicaçöes pós-operatórias mais frequentes foram a deiscência de sutura e a extrusäo do implante. A extrusäo do implante ocorreu mais frequentemente após a enucleaçäo


Subject(s)
Humans , Male , Female , Anophthalmos/surgery , Postoperative Complications/etiology , Endophthalmitis/complications , Eye Enucleation/methods , Eye Injuries/complications , Anophthalmos/etiology
SELECTION OF CITATIONS
SEARCH DETAIL